Kisheet for Windows 10 and 11. Buy once, priced per company. See pricing →
Try it live Pricing Compare
Company
FAQ About Contact
For mechanical & hvac estimators

HVAC takeoff, from duct run to pounds.

Trace duct by system, size and gauge for square feet of sheet and pounds with your fitting allowance. Elbows and tees come off the runs; air devices and VAVs count by tag.

Step by step

An HVAC ductwork bid in Kisheet, step by step.

A ductwork plan for a branch library: two rooftop units, a rectangular trunk stepping down in size, round branches to the diffusers, and a ceiling plenum return. Here is how it goes to square feet, pounds and counts.

The drawings are a sample set made for this guide. Every picture is a real screenshot of Kisheet, pre-release build of October 21, 2026.

  1. 1

    Make the duct and device tools

    Rectangular and round duct are runs; the diffusers and grilles are counts. One list makes the tool set, and Kisheet reads the scale printed under the plan.

    Tools › Tool Sets › New Tool Set from Excel or CSV; Tools › Measure › Use Printed Scale

    The Mechanical tool set in the tool palette beside the ductwork plan
    Kisheet, October 21, 2026
  2. 2

    Trace the trunk, size by size

    Click along each part of the trunk between its transitions. Every run shows its length, ready to be given its size.

    Pick the duct tool, click each end, double-click to finish

    The RTU-1 supply trunk traced in its six sizes on the ductwork plan
    Kisheet, October 21, 2026
  3. 3

    Size and gauge to square feet and pounds

    Give each run its size, 24x12 at the unit stepping down to 16x10, a gauge and a fitting allowance. Kisheet gives the square feet of sheet and the pounds for each.

    Select the run, then Properties › Duct

    The 24 by 12 inch trunk selected, with Properties showing its gauge, sheet area and weight
    Kisheet, October 21, 2026
  4. 4

    Find every 24x24 supply diffuser

    Pick the diffuser tool and drag a box round one. Visual Search finds every copy: S-1 and S-2 share the same 24x24 face, so they count together, the way they are priced. Each gets a mark to check by eye.

    Pick the count tool, then Tools › Visual Search › Visual Search, box one, then Count the Finds

    The supply diffusers found by Visual Search and counted on the ductwork plan
    Kisheet, October 21, 2026
  5. 5

    Elbows where the run turns

    Trace the RTU-2 run up to the staff wing and along it, give it its 14x10 size, then tick Count fittings. Kisheet counts an elbow wherever the run turns more than the angle you set, 30 degrees unless you change it.

    Select the run, then Properties › Count fittings

    The RTU-2 duct run traced with an elbow counted where it turns
    Kisheet, October 21, 2026
  6. 6

    Read the totals

    Group the takeoff table by subject: duct length, sheet area and weight, the elbows, and the diffuser count.

    Takeoff table › Group by › Subject (here in its own window)

    The takeoff table grouped by subject with duct lengths, sheet area, weight, fittings and the diffuser count
    Kisheet, October 21, 2026
What you need, and how Kisheet does it

Built for how an HVAC bid comes together.

Duct by system and size

Rectangular and round duct presets from 6" round to 90×36 trunk, each with its gauge and fitting allowance, in your company color; runs total by subject.

Square feet and pounds

Pick rectangular (W × H) or round (Ø), a gauge from 26 to 16 ga or your own lb/sq ft, and a fitting allowance: Duct Area and Duct Weight fill in.

Elbows and tees

Tick Count fittings: elbows where the run turns, tees where a branch ends on the main.

Air devices and equipment by tag

Count Tags finds S-1, R-1, E-1 and VAV-1; Check Counts Against a Schedule flags any type, device or unit, that doesn't match.

Flex and accessories

A formula column adds flex per device.

Piping and hangers

Trace CHW, HHW, refrigerant and condensate as their own tools, size in the label, and draw a hanger tool on the same run for one every 8 to 10 ft.

Duct wrap

Take the wrap off as its own run along the duct.

Typical floors and addenda

Repeats counted once, and every change listed before and after.